When the cooling system becomes contaminated, the cooling system should be flushed
thoroughly to remove the contaminants.
This procedure is effective in removing contaminants caused by the use of improper coolants,
coolant at the end of its life, or some liquid chemical flushing agents. This procedure is NOT
effective for removing debris contamination caused by component failure, or the use of ‘stop
leak’ additives. When the system is contaminated by this type of debris, use the system flow
diagrams to identify components that may need replacement to restore proper system flow.
Do not use chemical flush agents.
Various methods and equipment can be used to flush the cooling system. If special equipment
is used, such as a back flusher, follow the manufacturer’s instruction.