Air Conditioning System Seal Replacement
Removal Procedure
- Disassemble the air conditioning refrigerant components.
- Cap or tape the open air conditioning refrigerant components immediately to prevent system contamination.

- Remove the sealing washer (1) from the air conditioning refrigerant component.
- Inspect the seal washer for signs of damage to help determine the root cause of the failure.
- Inspect the air conditioning refrigerant components for damage or burrs. Repair if necessary.
- DISCARD the sealing washer. Installation Procedure
- Inspect the new sealing washer for any signs of cracks, cuts, or damage. Do not use a damaged sealing washer.
- Remove the cap or tape from the air conditioning refrigerant components.

- Using a lint-free clean, dry cloth, clean the sealing surfaces of the air conditioning refrigerant components.
- Carefully install the NEW sealing washer (1) onto the air conditioning refrigerant component. The sealing washer (1) must completely bottom against the surface of the fitting.
- Assemble the remaining air conditioning refrigerant components.