Skip to content

Testing for Continuity

Special Tools EL-39200-B Digital Multimeter (DMM) For equivalent regional tools, refer to Special Tools. Danger: This procedure should not be performed on high voltage circuits. Performing this procedure on high voltage circuits may result in serious injury or death.

  1. Set the DMM to the Ω position.
  2. Disconnect the power feed (i.e. fuse, control module) from the suspect circuit.
  3. Disconnect the load.
  4. Select the MIN MAX function on the DMM.
  5. Connect one lead of the DMM to one end of the circuit to be tested.
  6. Connect the other lead of the DMM to the other end of the circuit.
  7. If the DMM displays low or no resistance, the circuit has good continuity. With a Test Lamp
  1. Remove the power feed (i.e. fuse, control module) from the suspect circuit.
  2. Disconnect the load.
  3. Connect one lead of the test lamp to one end of the circuit to be tested.
  4. Connect the other lead of the test lamp to battery positive voltage.
  5. Connect the other end of the circuit to ground.
  6. If the test lamp illuminates (full intensity), then the circuit has good continuity.