Skip to content

Stop_Start Disable, Inhibit, and Restart Reasons

Stop/Start Disable, Inhibit, and Restart Reasons

Scantool Parameter - Current Inhibit Reason System State Description Expected Value Recommended Check Next Step
Autostop Disable Reason - Transmission Range Engine Running Transmission not in Drive. No Ensure transmission is in drive. Stop/start will not function in manual mode. If OK: Inform Customer - Normal Disable Condition If not OK: Refer to transmission diagnostics.
Autostop Disable Reason - Passenger Compartment Heater On Engine Running Passenger Compartment Heater ON. No Turn off passenger compartment heater. As Required.
Autostop Disable Reason - Driver Exited Vehicle Engine Running Seat belt un buckled and driver’s door opened. No Make sure driver’s seatbelt is secured and driver’s door latch is closed. As Required.
Autostop Disable Reason - 12V Start Counter Exceeded Engine Running Backup Start Performed indicates that an autostop was prevented due to the expiration of backup start counter. If the motor generator cannot autostart the ICE, a calibratable number of No Determine cause of the previous no start condition. As Required.
© 20a2t3te Gmepntesr atol Mo tors. All right s reserved.
Scantool Parameter - Current Inhibit Reason System State Description Expected Value Recommended Check Next Step
start the engine with the 12V starter will be performed.
Autostop Disable Reason - Vehicle Inclination Engine Running Vehicle Grade indicates that an autostop was prevented (or an autostart was commanded) due to the current grade level of the vehicle. No Verify vehicle is not on level ground. If not OK: Verify Multi- Axis Accelerator Sensor.
Autostop Disable Reason - Remote Vehicle Start Request Engine Running Remote Start indicates the internal combustion engine has been requested to run through a remote start command. No Verify remote start operation. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Acceleration Request Engine Running Driveability indicates an autostart was command based on torque conditions requested from the driver (generally a tip-in on the throttle). When this condition is detected, autostops are disallowed. No Ensure accelerator pedal is fully released. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Transmission In Reverse Engine Running Transmission in reverse gear. No Ensure transmission is in drive. Stop/start will not function in any other mode. If OK: Inform Customer - Normal Disable Condition.
Scantool Parameter - Current Inhibit Reason System State Description Expected Value Recommended Check Next Step
Autostop Disable Reason - Reduced Engine Power Active Engine Running Reduced Power indicates that AutoStops are disallowed when a situation has been detected that causes the vehicle to operate with reduced power. No Check ECM DTC’s. As Required.
Autostop Disable Reason - HYBRID/EV Battery Pack Temperature Engine Running HV Battery Pack Temperature indicates Disallow AutoStops/Comm AutoStart when battery temperature is high. No and Ensure parameter in scan tool is not indicating high. Check DTC’s. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Transmission Range Engine Running Transmission Range indicates that an autostop was prevented (or an autostart was commanded) due to the selected transmission range. No Ensure transmission is in drive. Stop/start will not function in manual mode. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Ignition Switch Start Engine Running Key Forced AutoStart Request: The driver can request an autostart in park or neutral by cranking the key. Autostops are not allowed again until out of park/neutral. No As required. If OK: Inform Customer - Normal Disable Condition.
Scantool Parameter - Current Inhibit Reason System State Description Expected Value Recommended Check Next Step
Autostop Disable Reason - TCM Request Engine Running TCM Override indicates that AutoStops are disallowed based on transmission PRNDL position. No Ensure transmission is in drive. Stop/start will not function in manual mode. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - System Optimization Engine Running System Optimization indicates Command AutoStart based on overall system conditions (engine speed & torque optimization). When this condition is detected, AutoStops are disallowed. No Ensure vehicle is over 3MPH/5KMH before autostop is enabled. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - System Voltage Low Engine Running 12V battery state of function low. No Charge and test battery, operate vehicle for longer drives, check generator operation. As Required.
Autostop Disable Reason - Engine Coolant Temperature Out Of Range Engine Running Engine Coolant Temperature indicates that an autostop was prevented (or an autostart was commanded) due to engine coolant temperature out of range (high or low). No Ensure coolant temperature isn’t too high or low. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason Engine Running Catalyst indicates a No Ensure catalyst parameter isn’t If OK: Inform Customer -
© 202r3e qGueenseteradl Mo tors. All right s roeuset rovfe rda.nge.
Scantool Parameter - Current Inhibit Reason System State Description Expected Value Recommended Check Next Step
- Catalyst Test In Progress inhibit for Catalyst monitor from gas or Diesel. Normal Disable Condition.
Autostop Disable Reason - HO2S Test In Progress Engine Running Oxygen Sensor indicates a requested inhibit for Oxygen Sensor Monitor. No Ensure oxygen sensor parameter isn’t out of range. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Misfire Test In Progress Engine Running Misfire Monitor indicates a requested inhibit for Misfire Monitor. No Ensure no misfire detected in scan tool. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Catalyst not at Operating Temperature Engine Running Catalyst not at Operating Temperature. No Ensure Catalyst is within operating temperature. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Intake Manifold Temperature Too High Engine Running Engine Manifold Temperature indicates an inhibit due to high Manifold Temp. No Ensure Manifold Temperature isn’t high. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Engine Speed Test in Progress Engine Running Engine Speed Diagnostics indicates a requested inhibit due to Engine Speed diagnostics. No As Required. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - MAF sensor Test In Progress Engine Running Mass Air Flow Diagnostics indicates a requested inhibit due to MAF diagnostics. No Check ECM DTC’s. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason Engine Running Manifold Absolute No Check ECM DTC’s. If OK: Inform Customer -
© 2023 General Mo tors. All right s reserved.
Scantool Parameter - Current Inhibit Reason System State Description Expected Value Recommended Check Next Step
- MAP Sensor Test In Progress Pressure Diagnostics indicates a requested inhibit due to MAP diagnostics. Normal Disable Condition.
Autostop Disable Reason - Engine Oil Temperature Too High Engine Running Engine Oil Temp indicates an inhibit due to high Engine Oil Temp. No Check Oil temperature is not too high. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Engine Stop/Start Test in Progress Engine Running Starting System indicates an inhibit due to Engine Start Stop functions. No Ensure control functions are done before proper function of stop/start. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Engine Coolant Temperature Test In Progress Engine Running Engine Coolant Temperature indicates a requested inhibit due to low or high Engine Coolant Temperature. No Ensure control function is done before expecting stop/start to function. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - EVAP System Test In Progress Engine Running Evap System indicates a requested inhibit for Evap System Monitor. No Ensure control function is complete before stop/start can function. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Fuel Injector Test In Progress Engine Running Fuel Injector Diagnostics indicates a requested inhibit due to Fuel Injector diagnostics. No Ensure control function is complete before stop/start can function. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Fuel Pressure Test In Progress Engine Running Fuel Pressure indicates a requested inhibit for Fuel No Ensure control function is complete before If OK: Inform Customer - Normal Disable Condition.
© 2023 General Mo tors. All right s reserved.
Scantool Parameter - Current Inhibit Reason System State Description Expected Value Recommended Check Next Step
Pressure Pump monitor. stop/start can function.
Autostop Disable Reason - Fuel System Test In Progress Engine Running Fuel Systems indicates a requested inhibit for Fuel Systems monitor. No Ensure control function is complete before stop/start can function. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Parking Maneuver Detected Engine Running Parking maneuver detection indicates a requested inhibit due to parking maneuver active. No Check functionality after parking. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - High Engine Rotating Torque Engine Running Engine Friction indicates a requested inhibit due to cold engine, friction high. No Wait for vehicle to reach proper temperature. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - BARO Pressure Too Low Engine Running Ambient Air Pressure indicates a requested inhibit due to low Barometric Pressure. No Ensure barometric temperature isn’t too low in scan tool. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Fuel Temperature Too High Engine Running Boil Off Diagnostics indicates a requested inhibit due to Fuel Boil Off diagnostics. No Ensure fuel temperature isn’t too high. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - System Malfunction Engine Running Starting System indicates that a condition in the starting system has been detected that No Check ECM DTC’s. If OK: Inform Customer - Normal Disable Condition.
© 2w02o3u ldG epnre vraeln Mt o tors. All right s reserved.
Scantool Parameter - Current Inhibit Reason System State Description Expected Value Recommended Check Next Step
a re-start of the vehicle and thus, autostops, have been disabled.
Autostop Disable Reason - Turbocharger Temperature Too High Engine Running Turbo Temp indicates an inhibit due to high Turbo Temp. No Check ECM DTC’s. If OK: Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Hood Ajar Engine Running Hood not latched. No Ensure hood is closed and latched. If OK: Refer to Hood Ajar Malfunction. If not OK: close hood.
Autostop Disable Reason - ECM Request Engine Running ECM tasks are currently running that will not allow an autostop. No Autostop will function once the task is complete. Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Run/Crank Not Active Engine Running Vehicle must be in Run Mode. No Verify ECM Run/Crank signal. If OK: Inform Customer - Normal Disable Condition. If not OK: refer to Power Mode Mismatch.
Autostop Disable Reason - Minimum Engine Run Time Not Met Engine Running Engine must run a minimum time before stop/start is allowed. No Autostop will function once the minimum run time is met. Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Control Function Active Engine Running Scantool control function active. No Release control function in scantool. None
Autostop Disable Reason - Auxiliary Transmission Fluid Engine Running Transmission aux pump or accumulator not available. No Check for transmission DTCs, refer to automatic transmission As Required.
© 2023 General Mo tors. All right s reserved.
Scantool Parameter - Current Inhibit Reason System State Description Expected Value Recommended Check Next Step
Pump/Accumulat Not Available or service information.
Autostop Disable Reason - Engine Coolant Temperature Out of Range Engine Running Coolant temperature too hot or cold. No Verify cooling temperature is within normal operating values. If OK: Inform Customer - Normal Disable Condition. If not OK: Refer to Engine Heating and Cooling diagnostics.
Autostop Disable Reason - Invalid Data Received Engine Running ECM has received invalid data. No Check ECM DTC’s. As Required.
Autostop Disable Reason - Vehicle Speed Too High Engine Running Vehicle speed detected. No Ensure vehicle is at a complete stop. If OK: Inform Customer - Normal Disable Condition. If not OK: Refer to SI.
Autostop Disable Reason - Transmission Fluid Temperature Out of Range Engine Running Transmission temperature too hot or cold. No Verify transmission temperature is within normal operating values. If OK: Inform Customer - Normal Disable Condition. If not OK: Refer to transmission diagnostics.
Autostop Disable Reason - Brake Pedal Released Engine Running Brake pedal not pressed (enough). No Ensure brake pedal is pressed sufficiently to active autostop. If OK: Inform Customer - Normal Disable Condition. If not OK: Verify brake pedal switch operation and calibration.
Autostop Disable Reason - Brake Booster Weak Vacuum Engine Running Weak brake booster vacuum. No Ensure brake booster vacuum is within normal Check DTCs. Refer to brake booster diagnostics.
© 2023 General Mo tors. All right s reserved.
Scantool Parameter - Current Inhibit Reason System State Description Expected Value Recommended Check Next Step
operating values.
Autostop Disable Reason - Accelerator Pedal Pressed Engine Running Accelerator pedal pressed. No Ensure accelerator pedal is fully released. If OK: Inform Customer - Normal Disable Condition. If not OK: Ensure pedal sensor operation and calibration.
Autostop Disable Reason - A/C Request Engine Running HVAC system is requesting AC compressor due to high cabin temperature and/or humidity. No Allow cabin temperature/hum to reach setpoint, change setpoint, turn off blower. idity Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Low-Voltage Battery Voltage Low Engine Running 12V battery voltage is low. No Charge and test battery, operate vehicle for longer drives, check generator operation. As Required.
Autostop Disable Reason - Low-Voltage Battery State of Health Low Engine Running 12V battery has low state of health. No Charge and test battery, operate vehicle for longer drives, check generator operation. As Required.
Autostop Disable Reason - Low-Voltage Battery State of Charge Low Engine Running 12V battery state of charge is low. No Charge and test battery, operate vehicle for longer drives, check generator operation. As Required.
Autostop Disable Reason - Low-Voltage Battery Engine Running Excessive current draw is placing a high demand on the No Check electrical loads, turn off unnecessary Inform Customer - Normal Disable Condition.
© 202g3e nGeernaetorar.l Mo tors. All right s reserlovaedds..
Scantool Parameter - Current Inhibit Reason System State Description Expected Value Recommended Check Next Step
Discharge Current High
Autostop Disable Reason - Intake Manifold Weak Vacuum Engine Running Low manifold vacuum. No Verify manifold vacuum. Check DTCs, refer to SI.
Autostop Disable Reason - Engine Speed High Engine Running High idle condition. No Correct cause of high idle. Check DTCs, refer to SI.
Autostop Disable Reason - Wheel Slip Detected Engine Running Slippery road conditions. No Ensure good road conditions. Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Vehicle Speed Threshold Not Reached Engine Running Vehicle must reach a minimum speed. No Operate at sufficient speeds. Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Maximum Vehicle Stop Time Exceeded Engine Running Engine was shut off for maximum allowable off time. No Operate at sufficient speeds to reactivate. Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Starter System Malfunction Engine Running Starter System Inoperable. No Check ECM DTCs, refer to SI. As Required.
Autostop Disable Reason - System Malfunction Engine Running Starter System Inoperable. No Check for Vehicle DTCs. As Required.
Autostop Disable Reason - Stop/Start Select Switch Engine Running Switch not enabled. No Turn switch on. If OK: Inform Customer – Normal Disable Condition. If Not OK: refer to Stop/Start
© 2023 General Mo tors. All right s reserved.
Scantool Parameter - Current Inhibit Reason System State Description Expected Value Recommended Check Next Step
System Malfunction.
Autostop Disable Reason - Idle Boost Mode Active Engine Running Idle boost requested. No Check electrical loads, turn off unnecessary loads. Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Generator Load High Engine Running Excessive current draw is placing a high demand on the generator. No Check electrical loads, turn off unnecessary loads. Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Clutch Pedal Applied Engine Running Clutch pedal (manual trans) not released. No Ensure clutch pedal is released. If OK: Inform Customer - Normal Disable Condition. If not OK: Refer to clutch switch diagnostic and verify calibration.
Autostop Disable Reason - Low-Voltage Battery Temperature Out of Range Engine Running Battery temperature too cold or hot. No Ensure battery is kept within normal operating range. Inform Customer - Normal Disable Condition.
Autostop Disable Reason - Low-Voltage Battery State of Function Low Engine Running 12V battery state of function low. No Charge and test battery, operate vehicle for longer drives, check generator operation. As Required.

The following Autostart Inhibit parameters show why the engine is off or was turned off. There are a couple different things this can mean. Forced Off (Mostly Hybrid), Propulsion System Shutdown (Stall), Cannot Start Engine (Hybrid). Autostart Inhibit

Scantool Parameter - Current Inhibit Reason System State Description Expected Value Recommended Check Next Step
Autostart Inhibit Reason - Hood Ajar Engine off Hood not latched. No Ensure hood is closed and latched. If not OK: close hood.
Autostart Inhibit Reason - ECM Request Engine off ECM tasks are currently running that will not allow an autostart. No Autostop will function once the task is complete. Inform Customer - Normal Disable Condition.
Autostart Inhibit Reason - Run/Crank Not Active Engine off Vehicle must be in Run Mode. No Verify ECM Run/Crank signal. If OK: Inform Customer - Normal Disable Condition.
Autostart Inhibit Reason - System Malfunction Engine off Vehicle System Issue. No Check for Vehicle DTCs. As Required.
Autostart Inhibit Reason - Autostart Not Commanded Engine off Vehicle is in a normal autostop mode. Yes None Inform Customer - Normal Disable Condition.
Autostart Inhibit Reason - Crank Aborted Engine off ECM has disabled propulsion system No Check ECM DTCs. As Required.
Autostart Inhibit Reason - Control Function Active Engine off Scantool control function active. No Release control function in scantool. As Required.
Autostart Inhibit Reason - ECM Malfunction Engine off ECM has disabled propulsion system. No Check ECM DTCs. As Required.
Autostart Inhibit Reason - Autostart/Autost Malfunction Engine off op ECM has disabled propulsion system. No Check ECM DTCs. As Required.
Autostart Inhibit Reason Engine off Seat belt unbuckled and No Not in all vehicles. If OK: Inform Customer -
© 2023 General Mo tors. All right s Vreesriefryv seeda.t belt
Scantool Parameter - Current Inhibit Reason System State Description Expected Value Recommended Check Next Step
- Driver Exited Vehicle driver’s door opened. and driver’s door switches. Normal Disable Condition.
Autostart Inhibit Reason - Engine Coolant Temperature Out of Range Engine off Coolant temperature too hot or cold. No Verify cooling temperature is within normal operating values. If OK: Inform Customer - Normal Disable Condition.
Autostart Inhibit Reason - Remote Vehicle Start Disabled Engine off Remote Vehicle Start Disabled. No As Required. As Required.
Autostart Inhibit Reason - Calibration Override Engine off Calibration forced to shut off by calibration. No Verify cooling temperature is within normal operating values. If OK: Inform Customer - Normal Disable Condition.
Autostart Inhibit Reason - Compression Test Engine off Engine was forced to shut off following the completion of a compression test. No As Required. As Required.
Autostart Inhibit Reason - TCM Request Engine off TCM can force the engine off depending on transmission conditions. No As Required. If OK: Inform Customer - Normal Disable Condition.
Autostart Inhibit Reason - Engine Stop Required Engine off Detection of a situation that might otherwise cause a stall of the vehicle. No As Required. As Required.

The following Autostart Reasons parameters are only valid when Engine is Running. It indicates why we started the engine the last time it was autostarted. Autostart Reasons

Scantool Parameter - Current Inhibit Reason System State Description Expected Value Recommended Check Next Step
Autostart Reason - TCM Demand Engine Running TCM has requested an autostart. No Ensure transmission is in drive. Stop/start will not function in manual mode. If OK: Inform Customer - Normal Disable Condition. If not OK: Refer to transmission diagnostics.
Autostart Reason - Reduced Engine Power Active Engine Running ECM has requested Reduced Engine Power No Check ECM DTCs. As Required.
Autostart Reason - Maximum Autostop Time Exceeded Engine Running Maximum autostop time is limited. No Maximum autostop time is typically 2 minutes. If OK: Inform Customer - Normal Disable Condition.
Autostart Reason - Transmission Fluid Temperature Out of Range Engine Running Transmission temperature too hot or cold. No Verify transmission temperature is within normal operating values. If OK: Inform Customer - Normal Disable Condition. If not OK: Refer to transmission diagnostics.
Autostart Reason - System Malfunction Engine Running Vehicle System Issue. No Check for Vehicle DTCs. As Required.
Autostart Reason - Transmission in Reverse Engine Running Transmission was placed in reverse. No Ensure transmission is in drive. If OK: Inform Customer - Normal Disable Condition. If not OK: Refer to transmission diagnostics.
Autostart Reason - Invalid Data Received Engine Running ECM has received invalid data. No Check ECM DTCs. As Required.
Scantool Parameter - Current Inhibit Reason System State Description Expected Value Recommended Check Next Step
Autostart Reason - Vehicle Speed Too High Engine Running Vehicle speed detected. No Ensure vehicle is at a complete stop. If OK: Inform Customer - Normal Disable Condition.
Autostart Reason - System Optimization Engine Running ECM has determined that the engine needs to be started. No Check DTCs. If OK: Inform Customer - Normal Disable Condition.
Autostart Reason - System Voltage Low Engine Running 12V battery state of charge is low. No Charge and test battery, operate vehicle for longer drives, check generator operation. If OK: Inform Customer - Normal Disable Condition.
Autostart Reason - Acceleration Request Engine Running Accelerator pedal pressed. No Ensure accelerator pedal is fully released. If OK: Inform Customer - Normal Disable Condition.
Autostart Reason - Minimum Engine Run Time Not Met Engine Running Engine must run a minimum time before stop/start is allowed. No Autostop will function once the minimum run time is met. Inform Customer - Normal Disable Condition.
Autostart Reason - Control Function Active Engine Running Scantool control function active. No Release control function in scantool. As Required.
Autostart Reason - Auxiliary Transmission Fluid Pump/Accumulat Not Available Engine Running or Transmission aux pump or accumulator not available. No Check for transmission DTCs, refer to automatic transmission service information. As Required.
Autostart Reason - Engine Coolant Temperature Out of Range Engine Running Coolant temperature too hot or cold. No Verify cooling temperature is within normal operating values. If OK: Inform Customer - Normal Disable Condition.
Scantool Parameter - Current Inhibit Reason System State Description Expected Value Recommended Check Next Step
Autostart Reason - Transmission Range Engine Running Transmission not in Drive. No Ensure transmission is in drive. Stop/start will not function in manual mode. If OK: Inform Customer - Normal Disable Condition.
Autostart Reason - Hood Ajar Engine Running Hood not latched. No Ensure hood is closed and latched. If not OK: close hood.
Autostart Reason - ECM Request Engine Running ECM tasks are currently running that will not allow an autostop. No Autostop will function once the task is complete. Inform Customer - Normal Disable Condition.
Autostart Reason - Low- Voltage Battery Discharge Current High Engine Running Excessive current draw is placing a high demand on the generator. No Check electrical loads, turn off unnecessary loads. Inform Customer - Normal Disable Condition.
Autostart Reason - Brake Pedal Released Engine Running Brake pedal not pressed (enough). No Ensure brake pedal is pressed sufficiently to active autostop. If OK: Inform Customer - Normal Disable Condition.
Autostart Reason - Brake Booster Weak Vacuum Engine Running Weak brake booster vacuum. No Ensure brake booster vacuum is within normal operating values. Check DTCs. Refer to brake booster diagnostics.
Autostart Reason - Accelerator Pedal Pressed Engine Running Accelerator pedal pressed. No Ensure accelerator pedal is fully released. If OK: Inform Customer - Normal Disable Condition.
Autostart Reason - A/C Request Engine Running HVAC system is requesting AC compressor due to high cabin temperature No Allow cabin temperature/hu to reach setpoint, change setpoint, turn off blower. Inform midiCtyustomer - Normal Disable Condition.
© 2023 General Mo tors. All right s reserved.
Scantool Parameter - Current Inhibit Reason System State Description Expected Value Recommended Check Next Step
and/or humidity.
Autostart Reason - Low- Voltage Battery Voltage Low Engine Running 12V battery voltage is low. No Charge and test battery, operate vehicle for longer drives, check generator operation. As Required.
Autostart Reason - Driver Exited Vehicle Engine Running Seat belt unbuckled and driver’s door opened. No Not in all vehicles. Verify seat belt and driver’s door switches. If OK: Inform Customer - Normal Disable Condition.
Autostart Reason - Passenger Compartment Heater On Engine Running Passenger Compartment Heater On. No Check Vehicle DTCs. If OK: Inform Customer - Normal Disable Condition.
Autostart Reason - Stop/Start select Switch Engine Running Stop/Start select Switch off. No Not in all vehicles. If OK: Inform Customer - Normal Disable Condition.
Autostart Reason - Driver Exited Vehicle Engine Running Seat belt unbuckled and driver’s door opened. No Not in all vehicles. Verify seat belt and driver’s door switches. If OK: Inform Customer - Normal Disable Condition.
Autostart Reason - Low Voltage Battery State of Charge Low Engine Running 12V battery voltage is low. No Charge and test battery, operate vehicle for longer drives, check generator operation. As Required.
Autostart Reason - Inclination Engine Running Vehicle Grade indicates that an autostop was prevented (or an autostart was commanded) due to the No As Required. If OK: Inform Customer - Normal Disable Condition.
© 2023 General Mo tors. All right s reserved.
Scantool Parameter - Current Inhibit Reason System State Description Expected Value Recommended Check Next Step
current grade level of the vehicle.
Autostart Reason - Low Voltage Battery State of Function Low Engine Running 12V battery voltage is low. No Charge and test battery, operate vehicle for longer drives, check generator operation. As Required.
Autostart Reason - Remote Vehicle Start Request Engine Running Remote Start Requested. No As Required. If OK: Inform Customer - Normal Disable Condition.
Autostart Reason - Ignition Switch Start Engine Running Switch Start Request. No The driver can request an autostart in park or neutral by cranking the key. Autostops are not allowed again until out of park/neutral. If OK: Inform Customer - Normal Disable Condition.
Autostart Reason - Low Voltage Battery State of Health Low Engine Running 12V battery voltage is low. No Charge and test battery, operate vehicle for longer drives, check generator operation. As Required.